​10kW On-Grid to 5kW Hybrid Automatic DC String Switcher Panel | Solar ATS

 






10kW On-Grid se 4kW DC String Shifting ATS Panel: Load Shedding ka Zabardast Hal

​Pakistan ke kai ilaqon mein load-shedding ka masla aam hai, khas kar jab light chali jaye to On-Grid solar systems band ho jatay hain aur inverter kaam nahi karta. Is maslay ka aik behtareen aur smart hal yeh nikala gaya hai ke 10kW On-Grid Inverter ki aik string (jismein 640W ke 7 panels yaani lagbhag 4kW ki string hai) ko automatic tareeqay se 5kW Hybrid Inverter (Crown waghera) par shift kar diya jaye jab bhi grid ki light jaye.

​Is system ka sabse bara faida yeh hai ke client ko mazeed naye solar panels khareedne aur lagane ki zaroorat nahi parti, balki mojooda panels hi light na hone par hybrid inverter ko chalanay lagtay hain.

​🛠️ Material Details (Istemal Shuda Maal)

​Is automatic DC string shifting ATS panel ko banane ke liye darj zail high-quality components istemal kiye gaye hain:

  • ​Power Contactors: Telemecanique / Schneider Electric ke heavy-duty LC1D2510 power contactors (jo high DC voltage aur current ko safe tarike se handle karte hain).

  • ​Control & Auxiliary Relays: System ki automatic shifting aur electrical interlocking ke liye control relays aur timers.
  • ​Protection Breakers: DC aur AC sides par safety ke liye MCBs aur protection fuses.
  • ​Enclosure Box: Wall-mounted high-quality metal distribution box jismein din-rail par saari wiring aur components ko tarteeb se fit kiya gaya hai.

  • ​Wiring: High-grade copper flexible wires (Control aur power connections ke liye alag-alag colors mein).

​⚡ Working & Installation Details (Kaam karne ka Tariqa)

​Is automatic system ki working aur installation ka mukammil procedure yeh hai:

  1. ​DC String Division: 10kW On-Grid inverter ki double string mein se aik 4kW (7 panels) wali string ko is ATS panel ke input par laya jata hai.

  1. ​Contactor Interlocking: Panel ke andar do contactors ko is tarah configure kiya jata hai ke aik waqt mein sirf aik hi system (ya to On-Grid ya Hybrid) us solar string se connected ho. Is se short-circuit ya inverters ke back-feed hone ka koi khatra nahi rehta.
  2. ​Grid Sensing (Automatic Shifting):
    • ​Jab tak Grid Light On rehti hai, ATS system solar string ko direct On-Grid Inverter par rakhta hai taake normalization par full generation milti rahey.
    • ​Jaise hi Grid Light Off hoti hai (load-shedding hoti hai), control circuit aur relays instantaneous active ho kar string ko 5kW Hybrid Inverter par transfer kar dete hain. Light wapis aane par system dobara On-Grid par shift ho jata hai.

  3. ​Safety & Protection: High voltage DC arcing se bachnay ke liye contactor ke poles ko proper series configuration mein adjust kiya gaya hai, taake panels ki high voltage switching bilkul safe aur reliable ho.

Maintenance Bypass Switch Ka Maqsad:

ATS panel mein upar lagaya gaya heavy-duty selector switch system ki maintenance aur servicing ke liye hai. Agar kabhi contactor, relay, ya timer ko check ya repair karna ho, to is switch ki madad se ATS circuit ko bypass kar ke PV string ko manually direct On-Grid ya Hybrid inverter par chalaya ja sakta hai, taake inspection ke dauran bhi solar system band na ho aur safe maintenance ho sake.


  • 100% utilization of solar investment: Solar panels par jo paise lagaye hain unka poora poora istemal karna (kyunki aam taur par light jane par On-Grid panels kisi kaam ke nahi rehte, lekin aap ke is ATS panel se woh light jaane par bhi hybrid system par chalte rahenge).
  • ​Without spending extra money on additional PV modules: Bina naye/izaafi solar panels khareede.

4kW DC String Shifting ATS Panel for 10kW On-Grid & 5kW Hybrid Systems: The Ultimate Load-Shedding Solution

​Load-shedding is a common issue in many regions, causing standard On-Grid solar systems to shut down whenever the main utility grid goes offline. To overcome this limitation, a smart and practical solution was designed: an automatic DC String Shifting ATS (Automatic Transfer System) Panel.

​This panel automatically transfers a 4kW string (consisting of seven 640W panels) from a 10kW On-Grid inverter to a 5kW Hybrid inverter (such as Crown) whenever the grid power fails. The primary benefit of this design is cost efficiency—the client does not need to purchase or install additional solar panels. Instead, the existing panels are dual-utilized across both systems dynamically.

​🛠️ Bill of Materials (Component Specifications)

​To construct this automatic DC string shifting ATS panel, high-grade components were selected to ensure reliability and high-voltage DC protection:

  • ​Power Contactors: Telemecanique / Schneider Electric heavy-duty LC1D2510 power contactors, configured for high-voltage DC load switching.

  • ​Control & Auxiliary Relays: High-quality industrial control relays (such as Relpol) combined with timer relays for smooth electrical interlocking and automatic shifting logic.

  • ​Protection Devices: Dedicated AC/DC Miniature Circuit Breakers (MCBs) and protective fuses for circuit safety.

  • ​Enclosure Box: Wall-mounted metal distribution enclosure with DIN-rail mounting for clean, organized cable management.

  • ​Wiring: Multi-strand copper flexible wiring, color-coded for control (yellow/red/blue) and power connections.

​⚡ Technical Working & Installation Details

​The complete operational flow and safety design of the panel are detailed below:

  1. ​DC String Splitting: Out of the total PV array connected to the 10kW On-Grid inverter, one 4kW string (7 panels) is routed directly to the input of this ATS panel.

  1. ​Electrical Interlocking: The two power contactors are electrically interlocked using auxiliary contacts to prevent both inverters from connecting to the same PV string simultaneously, eliminating back-feed or short-circuit risks.

  1. ​Automatic Grid Sensing & Shifting:
    • ​Grid Available (Light ON): The control circuit holds the On-Grid contactor energized, routing the 4kW PV string to the 10kW On-Grid inverter for maximum grid-tied generation.

    • ​Grid Failure (Light OFF): The control circuit instantly drops the On-Grid contactor and energizes the Hybrid contactor, transferring the string to the 5kW Hybrid inverter to power essential loads during power outages. When grid power returns, a time-delay relay smoothly shifts the string back to the On-Grid system.

  2. ​DC Arc Suppression Safety: To safely interrupt ~350V DC without damaging contactor points or creating fire hazards, the contactor main power poles are wired in series. This divides the DC arc voltage across multiple contacts during switching, extending contactor life and ensuring safe operation.
  3. ​🔄 Manual Maintenance Bypass Selector Switch

    ​To ensure seamless operations and safety during panel servicing, a heavy-duty Rotary Bypass Selector Switch has been integrated into the upper power section of the ATS panel:

    • ​Purpose & Functionality: During ATS panel maintenance, repair, or relay testing, this selector switch allows the technician to manually bypass the automatic contactor logic.
    • ​Continuous System Uptime: It enables direct routing of the PV string to either the On-Grid or Hybrid inverter manually without shutting down the entire solar array or interrupting power supply during system inspection.
    • ​Safety Isolation: Provides an additional manual override layer for isolation, preventing unexpected automatic switching during routine maintenance.

​This project serves as an ideal reference for solar clients who want 100% utilization of their solar investment during load-shedding without spending extra money on additional PV modules.





1 comment:

  1. Zabardast kaam hai Sameer bhai — on-grid system load shedding mein band ho jata hai, aur aap ka ATS panel usi 4kW string ko hybrid par shift kar ke investment ko zaya honay se bachata hai. Schneider LC1D2510 contactors aur interlocking ka zikr bohat ahem hai, kyun ke DC arcing se bachna is kaam mein sab se zaroori hai. Jo log apna system plan kar rahe hain, un ke liye solar inverter price in Pakistan bhi dekh lena faida-mand rahe ga. Shukriya!

    ReplyDelete

Find Us on Google Maps

📍

Electrician Sameer Ali

"Hamari service istemal karain, agar achi lagge to apni qeemti rae dain. Aapka mashkoor, Sameer Ali"

Review QR Code

Scan to Give Review 📱

Google Map par Dekhein Review Dein ⭐⭐⭐⭐⭐

Ev.chaerger

​Complete Panel Redressing & Dual System (On-Grid + Hybrid / EPS) Setup: Fault Solution, Load Balancing & Pros/Cons

  Viral video face book ​مکمل پینل ری ڈریسنگ، فالٹ حل، ڈوئل سسٹم سیٹ اپ اور فوائد و نقصانات ​اس سائٹ پر کسٹمر کے پاس تھری فیز آن گرڈ (3...

All time papular post