Inverex Solar Inverter: Mukammil Error Codes aur Solutions.
Repairing bhi kerwate Hain jinki warranty khatam hojati he..
Agar aapke solar inverter ki screen par koi Error Code nazar aa raha hai, to iska matlab hai ke system mein koi technical masla hai. Niche aam taur par aane wale codes aur unka hal diya gaya hai:
Common Error Codes Table
|
Error Code |
Masla (Fault) |
Waja aur Hal |
|---|---|---|
|
01 |
Fan Locked |
Inverter ka cooling fan jam hai. Ise saaf karein ya tabdeel karein. |
|
02 |
Over Temperature |
Inverter bohot garam ho gaya hai. Ventilation behtar karein. |
|
03/13 |
PV Over Voltage |
Solar panels ke voltage inverter ki limit se zyada hain. |
|
04 |
Battery Low |
Battery charge nahi hai. Solar ya Grid se charging check karein. |
|
06 |
Output Abnormal |
Output voltage had se barh gaye hain. System restart karein. |
|
07 |
Overload |
Inverter ki taqat se zyada load dala gaya hai. Load kam karein. |
|
08 |
Bus Voltage High |
Internal DC Bus voltage zyada hai. Surge ya hardware fault ho sakta hai. |
|
09 |
Bus Soft Start Failed |
Internal component short hone ka khatra. Technical repair lazmi hai. |
|
57 |
Current Sensor Failed |
Inverter ka internal current sensor kharab hai. |
|
59 |
Current Abnormal |
Inverter ke internal circuit mein achanak surge ya leakage. |
Solar Inverter Error Codes: Wajuhat aur Unka Hal Another brand inverter
Solar system ki karkardagi ka daromadar mukammal taur par inverter par hota hai. Aksar inverter ki screen par mukhtalif "Error Codes" nazar aate hain jo system mein kisi kharabi ki nishandehi karte hain. In errors ko samajhna zaroori hai taake aapka system mahfooz rahe.
Niche aam taur par nazar aane wale ahem error codes aur unka hal diya gaya hai:
1. PV Over Voltage (Error 03/13)
- Waja: Solar panels se aane wala voltage inverter ki bardasht se zyada ho gaya hai.
- Hal: Solar strings ke voltage check karein aur panels ki series/parallel setting ko inverter ki specification ke mutabiq drust karein.
2. Battery Under Voltage (Error 04)
- Waja: Battery ka voltage bohot kam ho gaya hai, jis ki waja se inverter "Low Battery" mode mein chala gaya hai.
- Hal: Check karein ke battery charge ho rahi hai ya nahi. Agar battery purani hai, to uski gravity ya health check karwayein.
3. Overload (Error 07)
- Waja: Inverter ki taqat se zyada bijli ka load dala gaya hai.
- Hal: Ghar ke faltu appliances (AC, Motor, etc.) band karein aur load ko inverter ki capacity ke mutabiq kam karein.
4. Over Temperature (Error 02)
- Waja: Inverter bohot zyada garam ho gaya hai.
- Hal: Inverter ke fans check karein ke wo chal rahe hain ya nahi. Inverter ko aisi jagah lagayein jahan hawa ka guzar behtar ho.
5. Grid Lost / No Grid
- Waja: Wapda ya grid ki supply band hai ya voltage bohot zyada/kam hain.
- Hal: Sub-breaker ya main circuit breaker check karein. Agar grid ke voltage ghair-mustahkim hain to inverter safety ke liye disconnect ho jata hai.
Mazeed Ahem Error Codes aur Unka Hal
6. Fan Locked (Error 01)
- Waja: Inverter ka cooling fan jam ho gaya hai ya usmein dhool mitti phans gayi hai.
- Hal: Fan ko saaf karein ya check karein ke koi cheez fan ke paron mein to nahi phansi. Agar fan kharab hai to ise fauri tabdeel karein taake inverter overheat na ho.
7. High Output Voltage / Inverter Soft Start Failed (Error 06)
- Waja: Inverter ke andaruni circuit (internal hardware) mein kharabi ya output voltage ka had se barh jana.
- Hal: Inverter ko ek baar mukammal off karke dobara restart karein. Agar masla barkarar rahe to hardware repair ki zaroorat ho sakti hai.
8. Bus Soft Start Failed (Error 09)
- Waja: Yeh ek technical hardware fault hai jo aksar internal component ke short hone ki wajah se aata hai.
- Hal: Is error ki surat mein khud koshish na karein aur fauri taur par kisi expert technician ya service center se rabta karein.
11. Bus Voltage Too High (Error 08)
- Waja: Inverter ke andaruni "DC Bus" ka voltage had se barh gaya hai. Iski aam wajuhat mein achanak bijli ka jhatka (Surge), solar panels ke voltage ka sudden high hona, ya inverter ke internal capacitors/IGBTs mein kharabi shamil ho sakti hai.
- Hal: 1. Fauri taur par Inverter ko OFF karein aur Solar (PV) aur Battery dono ke breakers gira dein. 2. Kuch dair baad dobara on karke check karein. 3. Agar yeh masla bar bar aa raha hai, to iska matlab hai inverter ka internal voltage regulator board sahi kaam nahi kar raha. Ise mazeed chalana khatarnak ho sakta hai, lihaza repair center se rabta karein.
Inverter ki Hifazat ke Liye Kuch Zaruri Mashwaray:
- Earthing: Inverter aur panels ki proper earthing lazmi karwayein taake bijli girne ya short circuit se bacha ja sake.
- Safai: Inverter ke cooling fans aur filters ki mahana safai karein.
- Breakers ka Istemal: AC, DC aur Battery ke liye alag se achi quality ke breakers aur SPDs lazmi lagayein.
Note: Agar error code bar bar aye ya inverter reset karne se khatam na ho, to hamesha kisi mustanad technician se rabta karein.
Lithium Battery aur Error 08 ka Talluq
Lithium battery istemal karte waqt agar aapne "Bulk Charging Voltage" aur "Float Voltage" ki settings battery ki makhsoos limit (Datasheet) se zyada rakhi hon, to bhi DC Bus voltage high hone ka khatra hota hai.
- Tip: Lithium battery ke liye hamesha BMS Communication ka istemal karein taake battery khud inverter ko bataye ke usey kitna voltage chahiye. Is se Error 08 aane ke chances bohot kam ho jate hain.